When the Smoke Moves In: How Better Airflow Data Can Help Schools Protect Indoor Air

Nov 17
4 min read

Wildfire smoke can travel hundreds or even thousands of miles from its source. A fire does not have to be visible from a classroom window to affect the air entering a school, childcare center, or other community building.


Wildfire burns along a dark hillside, with thick gray smoke rising into the sky and orange flames tracing the ridge.

A new study published in Environmental Research examined wildfire-smoke exposure at 115,612 public schools and 131,372 childcare centers across the United States from 2006 through 2023. The researchers found that the average number of annual smoke days increased from 6.8 to 54.4 at schools and from 9.4 to 112.2 at childcare centers during that period. In 2023 alone, the researchers calculated approximately 2.64 billion student-smoke-days at schools and another 1.02 billion at childcare centers.


The geography of the findings is especially noteworthy. While western states experienced the most severe smoke days, facilities in the South and Midwest recorded the highest numbers of smoke-affected days. That makes this an important issue for Kentucky and the surrounding region, not simply a distant environmental problem.


Buildings Do Not All Respond to Smoke the Same Way


The study also evaluated indoor and outdoor fine-particulate concentrations at a smaller group of West Coast facilities. Its conclusion was clear: educational buildings provide variable levels of protection against outdoor wildfire smoke.


Some buildings limit particulate infiltration more effectively than others, depending on factors such as filtration, envelope leakage, ventilation design, building pressure, equipment condition, and how the HVAC system is operated.

That variability creates a practical challenge for facility teams.


During normal conditions, schools need enough outdoor air to dilute indoor contaminants and support healthy learning environments. During a wildfire-smoke event, however, bringing in unnecessary outdoor air can increase the amount of fine particulate matter entering the building. Simply closing an outdoor-air damper is not necessarily a safe or complete solution. Reducing outdoor air too aggressively can allow carbon dioxide and other internally generated contaminants to build up, while poor building pressure can draw unfiltered air through doors, cracks, and other leakage paths.


The objective is not to eliminate ventilation. It is to operate the building deliberately, using filtration, airflow, pressure, occupancy, and air-quality information together.


You Cannot Control What You Are Not Measuring


A building automation system may command an outdoor-air damper to a particular position, but damper position is not the same thing as verified airflow.

Wind, dirty filters, fan speed, duct conditions, pressure changes, and mechanical wear can all affect how much air actually moves through the system. A damper at 30% open does not necessarily deliver 30% of design airflow. During a smoke event, that difference can matter.


This is where EBTRON thermal-dispersion airflow measurement can strengthen an indoor-air-quality strategy.


EBTRON devices can continuously measure airflow in outdoor, supply, return, and exhaust-air applications. That information can help a building automation system and its operators verify ventilation rates, maintain intended building pressure, identify abnormal conditions, and document how the HVAC system performed during changing outdoor-air conditions.


EBTRON’s multipoint technology uses precision bead-in-glass thermistors to measure air velocity and temperature at multiple locations across an airstream. The individual sensor nodes are factory calibrated to NIST-traceable standards, with stated airflow accuracy of ±2% of reading and temperature accuracy of ±0.08°C.


Building a More Responsive Smoke Strategy


Airflow measurement does not remove smoke by itself, and it should not be presented as a substitute for appropriate particulate filtration. Its value is that it provides the HVAC system with reliable information to support better decisions.


A smoke-response sequence might incorporate:

  • Outdoor-air quality or PM2.5 data

  • Measured outdoor airflow

  • Measured supply and exhaust airflow

  • Indoor carbon-dioxide levels

  • Filter pressure-drop monitoring

  • Building pressure

  • Occupancy information

  • Adjustable ventilation and fan-speed setpoints

  • Alerts when actual airflow differs from commanded or expected airflow


When outdoor particulate levels rise, the building automation system may temporarily reduce outside air to an established minimum, increase recirculation where the system allows it, and monitor indoor conditions. Actual airflow measurement helps confirm that the intended reduced ventilation rate is really being delivered.


Differential airflow tracking can also help maintain appropriate building pressure. In many facilities, maintaining controlled positive pressure can reduce the amount of unfiltered outdoor air infiltrating through the building envelope. EBTRON offers solutions for outdoor-air measurement, fan-inlet measurement, bleed-air measurement, damper and airflow combinations, room sensing, and differential airflow applications.


For centralized visibility, the EBTRON IAQ Enforcer SDX-1000 can connect with as many as 20 compatible EBTRON devices, providing live readings, device setup, and built-in applications through a touchscreen interface.


From Reactive to Prepared


The research reinforces an important shift in how schools should approach wildfire smoke. Smoke events cannot always be treated as rare emergencies. For many facilities, they are becoming a recurring operating condition that should be incorporated into commissioning, controls programming, maintenance planning, and emergency-response procedures.


A practical preparedness plan should include:


  1. Verify current ventilation rates. Confirm actual outdoor, supply, return, and exhaust airflow instead of relying only on damper commands or original design values.


  2. Evaluate filtration capability. Review filter efficiency, fan capacity, filter-rack condition, bypass leakage, and the pressure implications of any proposed filtration upgrade.


  3. Check building pressure. Determine whether the facility remains appropriately pressurized under normal, occupied, economizer, and smoke-response modes.


  4. Create a documented smoke sequence. Establish how the system will respond to elevated outdoor PM2.5 while maintaining acceptable indoor conditions and required ventilation.


  5. Trend the results. Record airflow, pressure, carbon dioxide, particulate, damper, and fan data so facility teams can confirm performance and refine the sequence over time.


Better Data Supports Better Protection


Schools and childcare centers cannot control when wildfire smoke reaches their communities. They can, however, improve how their buildings respond.


Accurate airflow measurement gives facility teams something more useful than an assumption. It provides continuous information about how much air is entering, leaving, and moving through the building. Combined with effective filtration, thoughtful control sequences, proper commissioning, and regular maintenance, EBTRON solutions can help turn an HVAC system into a more responsive part of a facility’s indoor-air-quality plan.


As smoke events become more frequent across the South, Midwest, and the rest of the country, that visibility will only become more valuable.


Research Reference


Foster, S. A., Kile, M. L., Larkin, A., MacDonald, M., McClelland, M. M., Salimifard, P., & Hystad, P. (2026). Spatio-temporal trends in wildfire smoke exposures at schools and childcare centers in the United States and implications for child and adolescent health. Environmental Research, 310(Part 2), Article 125883. https://doi.org/10.1016/j.envres.2026.125883

 
 
 

Comments


Commenting on this post isn't available anymore. Contact the site owner for more info.

Contact

Thanks for submitting!

Lexington Office

680 Bizzell Dr. Lexington, KY 40510

859.255.9665​

 

Louisville Office

13151 Middletown Industrial Blvd, Louisville, KY 40223

502.473.0829​

 

Paducah Office

115 Eaglet Cove, Paducah, KY 42003

​270.898.6976

  • Facebook
  • LinkedIn
bottom of page